Journal of Ultrasound in Medicine · 2012 · 85 citations · 23 references
MedicineRadiologyDiagnostic ImagingUltrasonographyUltrasoundBenign Thyroid DiseaseDiagnostic UltrasonographyThyroid ImagingThyroid Nodule EvaluationThyroid UltrasonographyUltrasound ImagingAcoustic Radiation ForceAcoustic Radiation Force Impulse ImagingBenign Nodule DifferentiationBenign Thyroid Nodule ImagingElasticity Imaging AssessmentMalignant Nodule DifferentiationThyroid AdenomasThyroid Elastography
OBJECTIVES: This study aimed to evaluate the diagnostic value of acoustic radiation force impulse (ARFI) elasticity imaging for differentiating between benign and malignant thyroid lesions. METHODS: Hospitalized patients needing thyroid surgery were evaluated. After routine thyroid sonography, the patients underwent ARFI elasticity imaging. Virtual Touch tissue imaging (VTI) and Virtual Touch tissue quantification (VTQ; Siemens Medical Solutions, Mountain View, CA) were used to qualitatively and quantitatively analyze the elasticity and hardness of nodules. For statistical analysis, the Student t test, analysis of variance, and the χ(2) test were used to compare the elastic parameters. RESULTS: Of the 98 thyroid nodules observed in 72 hospitalized patients, 56 were nodular goiters, 16 thyroid adenomas, 4 thyroiditis, and 22 thyroid malignancies, with mean VTQ values ± SD of 2.034 ± 0.484, 1.835 ± 0.364, 2.293 ± 0.787, and 3.941 ± 1.393 m/s, respectively. The elastic parameters of malignant nodules were significantly higher than those of benign nodules (P < .001) and the surrounding thyroid parenchyma (P < .001). There was no significant difference between the VTQ value of benign nodules and that of the surrounding normal thyroid parenchyma (P > .05). For differentiating between benign and malignant nodules, the sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accordance rate were 86.36%, 93.42%, 79.17%, 95.95%, and 91.84% based on the standard VTQ value (2.555m/s). In total, 77.6% (59 of 76) of the benign nodules showed softer and equal images in the VTI mode, and 77.3% (17 of 22) of the malignant nodules showed stiffer images (P < .001). CONCLUSIONS: Acoustic radiation force impulse imaging has high sensitivity and specificity in evaluating benign and malignant thyroid nodules and therefore had good diagnostic value in clinical applications.
23
Increasing Incidence of Thyroid Cancer in the United States, 1973-2002
Louise Davies, H. Gilbert Welch · JAMA · 2006 · 3.4K citations
Quantifying Hepatic Shear Modulus In Vivo Using Acoustic Radiation Force
Mark L. Palmeri, M.H. Wang, Jeremy Dahl et al. · Ultrasound in Medicine & Biology · 2008 · 683 citations · Full text
Natural Sciences, Physics, Radiology +14
Jack Yang, Vicki J. Schnadig, Roberto Logroño et al. · Cancer · 2007 · 683 citations · Full text