Journal of Feline Medicine and Surgery Open Reports · 2015 · 12 citations · 16 references
MedicineNeurologySurgeryNeuroanatomyNeuropathologySmall Animal SurgeryCentral Nervous SystemForeign Body RemovalForeign Body RetrievalFocal Neurological DeficitsNeedle Insertion ComplicationsNeurological DisabilityNeurological ObservationPostoperative Neurological DeficitsSurgical Foreign Body Extraction
CASE SUMMARY: A 1-year-old, female spayed domestic shorthair cat with a 6 week history of upper respiratory signs and a progressive reluctance to move, which culminated in a right-sided hemiparesis, was found to have a sewing needle foreign body lodged in the brainstem. Surgical extraction of the needle was successful and the cat's neurological deficits resolved over the days to weeks following its removal. RELEVANCE AND NOVEL INFORMATION: This case report describes, to our knowledge, the first reported incidence and management of an ingested sewing needle migrating into the central nervous system of a cat.
16
Pharyngeal stick penetration injuries in the dog
R. A. S. White, J. G. LANE · Journal of Small Animal Practice · 1988 · 55 citations