Physical Therapy · 2004 · 648 citations · 41 references
MedicinePhysical MedicineRehabilitation MedicinePhysical TherapyPsychometricsVestibular DisordersBalance AssessmentGait AnalysisGait AssessmentGait EvaluationVestibular RehabilitationClinical Gait AssessmentConsistencyDynamic Gait AssessmentGait FunctionInternal Consistency ReliabilityIntraclass CorrelationVestibular Disorder Assessment
The Functional Gait Assessment (FGA) is a 10‑item gait test derived from the Dynamic Gait Index. This study aimed to evaluate the reliability, internal consistency, and concurrent validity of the FGA in patients with vestibular disorders. Ten raters independently scored six patients on the FGA twice, with reliability assessed by intraclass correlation coefficients (ICC (2,1)) and internal consistency examined via Cronbach’s alpha and confirmatory factor analysis. The FGA achieved inter‑rater and intra‑rater ICCs of 0.86 and 0.74, a Cronbach’s alpha of 0.79, and Spearman correlations with balance measures ranging from 0.11 to 0.67, indicating acceptable reliability, internal consistency, and concurrent validity.
The Functional Gait Assessment (FGA) is a 10-item gait assessment based on the Dynamic Gait Index. The purpose of this study was to evaluate the reliability, internal consistency, and validity of data obtained with the FGA when used with people with vestibular disorders.Seven physical therapists from various practice settings, 3 physical therapist students, and 6 patients with vestibular disorders volunteered to participate.All raters were given 10 minutes to review the instructions, the test items, and the grading criteria for the FGA. The 10 raters concurrently rated the performance of the 6 patients on the FGA. Patients completed the FGA twice, with an hour's rest between sessions. Reliability of total FGA scores was assessed using intraclass correlation coefficients (2,1). Internal consistency of the FGA was assessed using the Cronbach alpha and confirmatory factor analysis. Concurrent validity was assessed using the correlation of the FGA scores with balance and gait measurements.Intraclass correlation coefficients of.86 and.74 were found for interrater and intrarater reliability of the total FGA scores. Internal consistency of the FGA scores was.79. Spearman rank order correlation coefficients of the FGA scores with balance measurements ranged from.11 to.67.The FGA demonstrates what we believe is acceptable reliability, internal consistency, and concurrent validity with other balance measures used for patients with vestibular disorders.
41
The Measurement of Observer Agreement for Categorical Data
J. Richard Landis, Gary G. Koch · Biometrics · 1977 · 78.9K citations · Full text