BMJ Open · 2015 · 10 citations · 10 references
MedicineClinical SciencesPharmacotherapyPulmonary Function TestingPulmonologyRespiratory PharmacotherapyChronic Obstructive Pulmonary DiseaseObstructive Lung DiseaseBronchodilator SafetyForced Expiratory Volume AssessmentForced Expiratory Volume DeclineForced Vital Capacity ChangeForced Vital Capacity RatioPost Hoc AnalysisPost Hoc Subgroup AnalysisPulmonary Exacerbations
OBJECTIVES: This post hoc analysis of TIOtropium Safety and Performance In Respimat (TIOSPIR) evaluated safety and exacerbation efficacy in patients with stable (≥ 2 months) use of tiotropium HandiHaler 18 µg (HH18) prior to study entry, to evaluate whether there was a difference in risk for patients who switched from HH18 to tiotropium Respimat 2.5 µg (R2.5) or 5 g (R5). SETTING: TIOSPIR (n=17,135) was an international, Phase IIIb/IV, randomised, double-blind, parallel-group, event-driven trial. PARTICIPANTS: Patients from TIOSPIR with chronic obstructive pulmonary disease (COPD) and postbronchodilator ratio of forced expiratory volume in 1 s to forced vital capacity ≤ 0.70, receiving HH18 before study entry, were analysed (n=2784). INTERVENTIONS: Patients were randomised to once-daily tiotropium R2.5 (n=914), R5 (n=918) or HH18 (n=952) for 2-3 years. PRIMARY OUTCOMES: time to death (safety) and time to first COPD exacerbation (efficacy). SECONDARY OUTCOMES: number of exacerbations and time to first major adverse cardiovascular event (MACE). RESULTS: Baseline characteristics were similar in all groups. Respimat had a similar mortality risk versus HH18 (vital status follow-up, HR; 95% CI R2.5: 0.87; 0.64 to 1.17; R5: 0.79; 0.58 to 1.07) with no significant differences in the risk and rates of exacerbations and severe exacerbations across treatment groups. Risk of MACE and fatal MACE was similar for Respimat versus HH18 (HR; 95% CI MACE R2.5: 0.73; 0.47 to 1.15; R5: 0.69; 0.44 to 1.08; fatal MACE R2.5: 0.57; 0.27 to 1.19; R5: 0.67; 0.33 to 1.34). Overall risk of a fatal event (on treatment) was lower for R5 versus HH18 (HR; 95% CI R2.5: 0.78; 0.55 to 1.09; R5: 0.62; 0.43 to 0.89). CONCLUSIONS: This analysis indicates that it is safe to switch patients from tiotropium HandiHaler to tiotropium Respimat, and that the efficacy is maintained over the switch. TRIAL REGISTRATION NUMBER: NCT01126437; Post-results.
10
A 4-Year Trial of Tiotropium in Chronic Obstructive Pulmonary Disease
Donald P. Tashkin, Bartolomé R. Celli, Stephen Senn et al. · New England Journal of Medicine · 2008 · 2.2K citations · Full text
Tiotropium Respimat Inhaler and the Risk of Death in COPD
Robert A. Wise, Antonio Anzueto, Ronald Dahl et al. · New England Journal of Medicine · 2013 · 334 citations
Tiotropium Respimat Inhaler and the Risk of Death in COPD
Robert A. Wise, Antonio Anzueto, Ronald Dahl et al. · Survey of Anesthesiology · 2014 · 82 citations