Strontium 87mSr bone scanning for the evaluation of total hip replacement
32
Citations
0
References
1976
Year
Bone ScanningSurgeryOsteoporosisOrthopaedic SurgeryOsteoarthritisTotal Hip ImplantJoint ReplacementArthroscopic TechniqueNuclear MedicineRadiologyHealth SciencesStrontium 87MsrMedical ImagingMusculoskeletal ImagingBone ImagingHip ArthroplastyTotal Hip ReplacementSeventeen PatientsMedicineSkeletal Imaging
In a series of seventeen patients with unilateral osteoarthritis of the hip a scintiscanning follow-up study was made before and after total hip replacement for the assessment of the normal course of the 87mSr-scintiscan. In another series of twenty-eight patients with total hip replacement a photoscan was made as a supplement for the diagnosis of loosening of one or both components of a total hip implant. In most of these cases it proved to be a useful method, especially when clinical and raidological examination was inconclusive. It is concluded that up to six months after operation increased osteoblastic activity exists; the scintiscan became normal after that time. 87mSr scintiscanning offers a safe and simple technique for the assessment of the success and stability of total hip arthroplasty. It is also a useful aid for the early detection of loosening and infection. The procedure can help in the differential diagnosis of complaints after total hip replacement.