Publication | Open Access
Safe Limits of Contrast Vary With Hydration Volume for Prevention of Contrast-Induced Nephropathy After Coronary Angiography Among Patients With a Relatively Low Risk of Contrast-Induced Nephropathy
48
Citations
23
References
2015
Year
Safe LimitsRenal PathologySufficient Hydration StatusHydration DataRenal FunctionVascular ImagingContrast VaryPublic HealthAcute Kidney InjuryChronic Kidney DiseaseRenal PharmacologyCardiologyRadiologyCardiovascular ImagingHemodialysisVascular ImageKidney FailureRenal PathophysiologyDiuretic ResistanceContrast AgentDigital Subtraction AngiographyCardiovascular DiseasePulmonary PhysiologyHydration VolumeMedicineNephrologyKidney ResearchAnesthesiology
Background— Few studies have investigated the safe limits of contrast to prevent contrast-induced nephropathy (CIN) based on hydration data. We aimed to investigate the relative safe maximum contrast volume adjusted for hydration volume in a population with a relatively low risk of CIN. Methods and Results— The ratios of contrast volume-to-creatinine clearance (V/CrCl) and hydration volume to body weight (HV/W) were determined in patients undergoing cardiac catheterization. Receiver–operator characteristic curve analysis based on the maximum Youden index was used to identify the optimal cutoff for V/CrCl in all patients and in HV/W subgroups. Eighty-six of 3273 (2.6%) patients with mean CrCl 71.89±27.02 mL/min developed CIN. Receiver–operator characteristic curve analysis indicated that a V/CrCl ratio of 2.44 was a fair discriminator for CIN in all patients (sensitivity, 73.3%; specificity, 70.4%). After adjustment for other confounders, V/CrCl >2.44 continued to be significantly associated with CIN (adjusted odds ratio, 4.12; P <0.001) and the risk of death (adjusted hazard ratio, 2.62; P <0.001). The mean HV/W was 12.18±7.40. We divided the patients into 2 groups (HV/W ≤12 and >12 mL/kg). The best cutoff value for V/CrCl was 1.87 (sensitivity, 67.9%; specificity, 64.4%; adjusted odds ratio, 3.24; P =0.011) in the insufficient hydration subgroup (HV/W, ≤12 mL/kg; CIN, 1.32%) and 2.93 (sensitivity, 69.0%; specificity, 65.0%; adjusted odds ratio, 3.04; P =0.004) in the sufficient hydration subgroup (HV/W, >12 mL/kg; CIN, 5.00%). Conclusions— The V/CrCl ratio adjusted for HV/W may be a more reliable predictor of CIN and even long-term outcomes after cardiac catheterization. We also found a higher best cutoff value for V/CrCl to predict CIN in patients with a relatively sufficient hydration status, which may be beneficial during decision-making about contrast dose limits in relatively low-risk patients with different hydration statuses.
| Year | Citations | |
|---|---|---|
Page 1
Page 1