Concepedia

Publication | Open Access

Tritium calibration of the LUX dark matter experiment

101

Citations

23

References

2016

Year

Abstract

We present measurements of the electron-recoil (ER) response of the LUX dark matter detector based upon 170 000 highly pure and spatially uniform tritium decays. We reconstruct the tritium energy spectrum using the combined energy model and find good agreement with expectations. We report the average charge and light yields of ER events in liquid xenon at 180 and $105\text{ }\text{ }\mathrm{V}/\mathrm{cm}$ and compare the results to the NEST model. We also measure the mean charge recombination fraction and its fluctuations, and we investigate the location and width of the LUX ER band. These results provide input to a reanalysis of the LUX run 3 weakly interacting massive particle search.

References

YearCitations

Page 1