Organic Impurities and Organic Conditioning Agents in the Steam/Water Cycle: A Power Plant Manufacturer's Point of View

R. Svoboda, F Gabrielli, Herbert Hehs, Hans-Günter Seipp, Frank‐Udo Leidich, Bruce Roberts

2006 · 11 citations · 0 references

Concepts

Abstract

Power plants are designed to run with pure water and steam. For simple cycles (no export steam) no other products should be necessary. If organic additives are used, the possible side effects have to be carefully addressed. Possible side effects include corrosive degradation products, interference with monitoring cation conductivity, influence on boiling and on condensation, and fouling. Examples from boiler and turbine operation are given.