In radiation backscattering, the radiation source and film or imaging plate are on the same side of the object. When radiation is incident from the source part will scatter back to a detector, film or imaging plate due to Compton interaction to form the image. In this work a narrow gamma ray beam was allowed to be incident on insulated carbon steel pipe whose diameter, wall thickness and asbestos insulation thickness were: 28 cm, 9 mm and 4 cm respectively. Radiation penetrates the insulator and upon interaction with the pipe iron wall the backscattered radiation from the pipe was measured by 2x2 NaI(Tl) detector with multichannel analyzer. The source was 5 mCi 137 Cs giving 7 mm diameter collimated gamma rays at the exit of the collimator. The source and detector were allowed to move together to scan the pipe by a mechanical scanning device. Radiation counts collected by the detector are sent to data storage device in a computer to construct the image using LABVIEW programs. Image of artificial defect of about 7 cm diameter with varying depth was successfully revealed.