2012 · 13 citations · 2 references
EngineeringNuclear EngineeringRadiation DetectionRadiation MeasurementRadiation PhysicsGamma-ray DetectionGamma-ray DetectorsRadiation DetectorsRadiation Imaging DetectorsRadiation Imaging SystemsRadiographic ImagingBackscatteringBackscattering EffectsCompton ImagingCompton ScatteringParticle BackscatteringRadiation Source Characterization
In radiation backscattering, the radiation source and film or imaging plate are on the same side of the object. When radiation is incident from the source part will scatter back to a detector, film or imaging plate due to Compton interaction to form the image. In this work a narrow gamma ray beam was allowed to be incident on insulated carbon steel pipe whose diameter, wall thickness and asbestos insulation thickness were: 28 cm, 9 mm and 4 cm respectively. Radiation penetrates the insulator and upon interaction with the pipe iron wall the backscattered radiation from the pipe was measured by 2x2 NaI(Tl) detector with multichannel analyzer. The source was 5 mCi 137 Cs giving 7 mm diameter collimated gamma rays at the exit of the collimator. The source and detector were allowed to move together to scan the pipe by a mechanical scanning device. Radiation counts collected by the detector are sent to data storage device in a computer to construct the image using LABVIEW programs. Image of artificial defect of about 7 cm diameter with varying depth was successfully revealed.
2