2011 · 17 citations · 20 references
EngineeringBioengineeringEnvironmental EngineeringBioreactor DesignWaste ManagementWastewater TreatmentBiodegradationLandfill EngineeringLandfill ManagementOrganic Waste ManagementOrganic Waste RecoveryWastewater BiotreatmentChemical Oxygen DemandHydraulic Retention TimeLandfill Leachate ManagementLandfill Leachate TreatmentLeachate BiotreatmentMoving Bed Biofilm ReactorsRemoval EfficiencyThermophilic Growth
In the present study the landfill leachate obtained from Tabriz Landfill site was first treated in a suspended growth activated sludge bioreactor which then was turned to a moving-bed biofilm bioreactor under thermophilic conditions (50ºC). The average Soluble Chemical Oxygen Demand (SCOD) removal ranged from 70 % to 62% as Organic Loading Rate (OLR) increased from 0.454 to 4.678 kgCOD/(m3.d). Hydraulic Retention Time (HRT) values were set to 12, 14, 16.8, and 21 h. The recycle ratio of biomass ranged from 1 to 1.5. The total biomass concentration was in the range of 2600-3100 mg/L of which 60-65 percent was in the form of biofilm. It was COD removal efficiency was 5 % to 10 % higher in moving-bed biofilm operation compared to suspended growth one at the same OLR and HRT. Respirometry experiments revealed that readily biodegradable organic compounds accounted for 5.7 % and 5.2 % of substrate under thermophilic and mesophilic conditions, respectively. The maximum resulting oxygen uptake rates were 0.21 mgO2/(L.min) and 0.16 mgO2/(L.min) under thermophilic and mesophilic conditions, respectively. Key words: Landfill leachate; Thermophilic; Aerobic; Moving bed biofilm bioreactor
20
Thermophilic aerobic biological wastewater treatment
Timothy M. LaPara · Water Research · 1999 · 223 citations