Measurement of Radium Content and Radon Exhalation Rates in Building Material Samples using Passive and Active Detecting Techniques

Zakariya A. Hussein, Mohamad Suhaimi Jaafar, Asaad H. Ismail, Salahaddin University-Erbil

2013 · 17 citations · 10 references

Concepts

Abstract

Experimental results concerning the radon concentration and radon exhalation rate from samples of building materials which were collected from the Iraqi Kurdistan using passive and active detecting techniques. the passive techniques, was used (CR-39NTDs) for a period of 2 month in each measurement. In the active techniques, was used (RAD7) for a duration of 24h for each samples. In both techniques, The highest and lowest of radon concentration was found in sand and ceramic tile samples respectively, It depends on the radioactive content of the materials, emanation factor and diffusion coefficient of radon in that material, porosity and density of the material. The radon exhalation rate varies from 115.85 ± 6.38 to 345.86 ± 6.82 (mBq/m 2 .h) and 14.46 ± 1.84 to 22.32 ± 2.12 (mBq/Kg.h) for different building materials. The exhalation rate is a function of diffusion length, which, in turn, depends on several physical parameters of the material humidity, porosity and geometry

References

10