2011 · 14 citations · 32 references
MedicineCell BiologyOncologyBreast OncologyCancer ImmunologyMolecular OncologyBioanalytical Method ValidationCancer BiomarkersCancer DetectionCirculating Tumor CellsEarly Cancer DetectionBlood Sample CollectionCirculating Tumor BiomarkersCirculating Tumor Cell BiomarkersCirculating Tumor Cell CharacterizationCirculating Tumor Cell EnumerationCirculating Tumor Cell MonitoringCirculating Tumor MarkersSpecimen Collection Tubes
Abstract Background: We compared two surface epithelialantigen (EpCAM)-based approaches for the detectionof breast cancer cells present in the circulation.Methods: Blood from 20 breast cancer patients wasdrawn into standard blood collection tubes (SBCT) andof 7 of these additionally into CellSave® tubes. Aftererythrocyte lysis of the samples from both systems,cells were stained with FITC-anti-EpCAM andpropidium iodide, quantified with an automatedmicroscope and intact cells counted.Results: EpCAM-positive events from 1ml of bloodranged between 2051 and 28875/ml and from SBCT(MAINTRAC® approach) as compared to between 97and 2343/ml from the CellSave® tubes, indicating amore than 10-fold reduction in EpCAM accessibility bythe preservative. Duplicate cell preparations showed ahigh correlation of R2=0.89 (MAINTRAC®) from SBCTvs. a moderate correlation of R2=0.81 from CellSave®tubes, but a good correlation (R2=0.91) between theevents detected from both systems.Between 1/2 and 1/5 of the positive events were viablecells in the MAINTRAC® approach with unequivocalmorphology, and a good (R2=0.89) correlation to totalevents; by contrast, 1/10 to less than 1/100 of theevents in the CellSave® tubes were perhaps cells withequivocal morphology no correlation to total eventsmost positive events being non-recognizable cells. Still30 to 100-fold more cells were recovered than with theCellTrack® Analyzer.Conclusions: The approach without fixative detectsconsiderably more EpCAM-positive events with goodcell morphology as compared to the CellSave®fixation where cell morphology is poor. Magnetic beadenrichment further reduces the number of retrievedcells.
32
Isolation of rare circulating tumour cells in cancer patients by microchip technology
Sunitha Nagrath, Lecia V. Sequist, Shyamala Maheswaran et al. · Nature · 2007 · 3.5K citations · Full text
Medicine, Cancer Biology, Oncology +15
Circulating Tumor Cells in Patients with Breast Cancer Dormancy
Songdong Meng, Debasish Tripathy, Eugene P. Frenkel et al. · Clinical Cancer Research · 2004 · 974 citations · Full text
Medicine, Cell Biology, Oncology +14