Effect of time on the diametral tensile strength of resin-modified restorative glass ionomer cements and compomer.

Daniela Francisca Gigo Cefaly, Fabrício Pinelli Valarelli, Bruno Seabra, RFL Mondelli, Maria Fidela de Lima Navarro

PubMed · 2001 · 32 citations · 17 references

Concepts

Abstract

The aim of this study was to analyze the diametral tensile strengths of three resin-modified restorative glass ionomer cements--Vitremer, Fuji II LC and Photac Fil and one compomer--Dyract. They were tested at 1 hour, 1 day and 1 week. Kratos testing machine was used to load the specimens at a cross-head speed of 0.5 mm/min. The data were analyzed by two-way ANOVA and Tukey's test that showed statistically significant differences among the materials. The tested materials presented an increase in strength from 1 hour to 1 week and were as follows for each material respectively: Vitremer (19.22-27.29), Fuji II LC (23.91-28.67), Photac Fil (19.35-22.86), Dyract (28.83-46.95). Dyract presented the highest strengths.

References

17