2014 · 23 citations · 6 references
ArchitectureArchitectural EngineeringBuilding ScienceBuilding Performance SimulationFacade DesignThermal ComfortBuilding Energy ModelingBuilding Thermal PerformanceDouble-skin FacadesFacade Energy PerformanceFacade TypologyThermal PerformanceComputational SimulationDouble-skin Facade DesignFacade Energy SimulationFacade Performance SimulationFacade Thermal DesignOffice Building DesignThermal Comfort In FacadesThermal Performance Modeling
Taking into account Mediterranean climate particularities for Barcelona, Spain, a whole year study using TAS simulation software was carried out for a Double Skin Façade corporative office building. It is a typical office building with an extended working hours schedule for acclimatization. Four different cavity widths were simulated – 40cm, 60cm, 80cm, 100cm- as well as three different external opening areas for cavity’s natural ventilation purpose. Two Double Skin Façade typologies were simulated – a corridor façade and a multistory façade. Simulations showed cooling loads are much greater than heating loads on a double glazed skin façade building south oriented in a Mediterranean climate town like Barcelona. Results demonstrated that a Multistory Façade, depending on its configuration, might save up to 5 % on annual cooling loads respect to a Corridor Façade. Different opening areas and cavity depths shall be used for different typologies in order to obtaining good energy results.
6