The Korean Journal of Orthodontics · 2015 · 37 citations · 27 references
DentistryOral RadiologyRadiologyDiagnostic ImagingDiagnostic RadiologyMaxillofacial ImagingCephalometric AnalysisCephalometric ImagingCephalometric RadiographyComputed TomographyThree-dimensional Cephalometric AnalysisThree-dimensional ReconstructionCephalometric AnglesCephalometric Angular MeasurementsCephalometric Morphometric AnalysisCone-beam Computed Tomography (Cbct)Craniofacial Morphometric AnalysisLateral Cephalometric RadiographyRepeated Measures AnalysisThree-dimensional Cephalometry
OBJECTIVE: This study investigated whether it is possible to use a two-dimensional (2D) standard in three-dimensional (3D) analysis, by comparing the angles and lengths measured from a midsagittal projection in 3D cone-beam computed tomography (CBCT) with those measured by 2D lateral cephalometric radiography (LCR). METHODS: Fifty patients who underwent both LCR and CBCT were selected as subjects. CBCT was reoriented in 3 different methods and the measuring-points were projected onto the midsagittal plane. Twelve angle values and 8 length values were measured on both LCR and CBCT and compared. RESULTS: Repeated measures analysis of the variance revealed statistically significant differences in 7 angular and 5 linear measurements among LCR and 3 types of CBCT (p < 0.05). Of these 12 measurements, multiple comparisons showed that 6 measurements (ANB, AB to FH, IMPA, FMA, Co-Gn, Go-Me) were not significantly different in pairwise comparisons. LCR was significantly different from 3 types of CBCT in 3 angular (SN to FH, interincisal angle, FMIA) and 2 linear (S-Go, Co-ANS) measurements. The CBCT method was similar for all measurements, except for 1 linear measurement, i.e., S-N. However, the disparity between the mean values for all parameters was within the range of clinical measurement error. CONCLUSIONS: 3D-CBCT analysis, using midsagittal projection, is a useful method in which the 2D-LCR normative values can be used. Although the measurements changed with reorientation, these changes were not clinically significant.
27
A NEW X-RAY TECHNIQUE and ITS APPLICATION TO ORTHODONTIA
B. Holly Broadbent · The Angle Orthodontist · 2009 · 1.1K citations · Full text
Accuracy of three-dimensional measurements using cone-beam CT
HM Pinsky, S Dyda, RW Pinsky et al. · Dentomaxillofacial Radiology · 2006 · 344 citations
Danielle R. Periago, William C. Scarfe, Mazyar Moshiri et al. · The Angle Orthodontist · 2007 · 320 citations · Full text
Comparison of conventional and cone beam CT synthesized cephalograms
Vandana Kumar, J B Ludlow, André Mol et al. · Dentomaxillofacial Radiology · 2007 · 238 citations · Full text
Ana Emília Figueiredo de Oliveira, Lucía Cevidanes, Ceib Phillips et al. · Oral Surgery Oral Medicine Oral Pathology Oral Radiology and Endodontology · 2008 · 205 citations
Dentistry, Oral Radiology, Radiology +16