2010 · 30 citations · 6 references
EngineeringArchitectural EngineeringMaterials EngineeringBuilding MaterialsHeat TransferStructural MaterialsInsulation MaterialsMasonry ConstructionMasonry MaterialsMasonry StructuresMoisture-resistant MaterialsThermal InsulationDynamic Hygrothermal ResponseFreeze-thaw DamageFreeze-thaw ResistanceFreeze-thaw TestingFreezing Resistance MechanismsMasonry Hygrothermal BehaviorMoisture BalanceWater Absorption
Older load-bearing brick masonry buildings are common throughout North America and are considered good candidates for renovation and conversion. Insulation retrofits are typically implemented as part of this work. The addition of insulation can change the thermal and moisture balance in the wall assembly and, in some cases, initiate moisture problems such as freeze-thaw damage in masonry units. Designers have used 2D heat flow and 1D dynamic hygrothermal models to predict the temperature and moisture conditions in these retrofitted wall assemblies. Unfortunately, there are few guidelines for assessing the susceptibility of clay brick to freeze-thaw problems. Two pass/fail tests have been used in the past to assess the freeze-thaw resistance of bricks: the cold water/boiling water absorption ratio (c/b ratio), and the 50-cycle freeze-thaw test. These approaches do not adequately represent the freezing mechanisms or conditions that bricks experience in the field. An alternative approach is suggested here: frost dilatometry can be used to determine the critical degree of saturation at which freeze-thaw damage is likely to occur. Informed design decisions can be made by
6