Oxidation‐reduction potential (<scp>ORP</scp>) as a control parameter in a single‐stage partial nitritation/anammox process treating reject water

Jingjing Yang, Józef Trela, Olle Wahlberg, Erik Levlin

Journal of Chemical Technology & Biotechnology · 2015 · 16 citations · 25 references

Concepts

Abstract

Abstract BACKGROUND Redox potential value (or pE ) can be used as a monitoring parameter for deammonification processes treating reject water. In this study its use as a control parameter was investigated. Experiments were carried out with a one‐stage partial nitritation/anammox process in a 200 L moving bed biofilm reactor ( MBBR ) with 40% filled Kaldnes biofilm carriers. RESULTS Tests on different combinations of nitrogen loads (1.8–3.3 gN m −2 d −1 ) and pE values (−1, 0, 1) revealed that process performance was stable and nitrogen removal efficiency &gt;80% was achieved at all tested pE values except pE = − 1. A value close to pE =0 was the most suitable in terms of process performance at 25°C at all tested pE values. With a fixed redox potential value ( pE =0) used in the system, the air supply adjusted automatically under different nitrogen loads and maintained a high nitrogen removal efficiency. Theoretical calculations showed that pE &gt;0.15 (at pH =7) provides conditions for nitrite conversion into nitrate at 25°C. CONCLUSION Redox control turned out to be a suitable control parameter for operation of a partial nitritation/anammox process. A redox value of 0 was a suitable value under different nitrogen loads in this pilot‐scale study. © 2015 Society of Chemical Industry

References

25