Publication | Open Access
Online stator winding fault diagnosis in inverter-fed ac machines using high-frequency signal injection
132
Citations
23
References
2003
Year
Fault DiagnosisCondition MonitoringOnline StatorElectrical EngineeringInverter-fed Ac MachinesEngineeringElectric MachineHigh-frequency Signal InjectionFundamental Excitation FrequencyHigh-frequency SignalFault DetectionAutomatic Fault Detection
The diagnosis of stator winding faults in inverter-fed AC machines using an injected high-frequency carrier signal is presented and analyzed in this paper. Measurement of the resulting high-frequency negative-sequence current (or alternatively of the negative-sequence impedance) is used to detect turn faults at an incipient stage. Though sharing the same physical principles of similar techniques applied to line-connected machines, the use of a high-frequency signal is shown to present important advantages, such as providing the same performance almost independently of the fundamental excitation frequency, and drastically reducing the sensitivity to the working condition of the machine, i.e., torque and flux levels.
| Year | Citations | |
|---|---|---|
Page 1
Page 1