NDT & E International · 2015 · 23 citations · 27 references
EngineeringCivil EngineeringAcousticsStructural EngineeringUltrasoundAcoustic MeasurementStructural Health MonitoringTransducer TechnologyUltrasonicsVibration MeasurementWave Propagation In StructuresCoda Wave AttenuationDamage Detection By WavesLock-in AmplificationUltrasonic InspectionUltrasonic TestingUltrasonic WavesVibration-based Monitoring
Measuring amplitude and phase of continuous ultrasonic waves with a lock-in amplifier is shown to give similarly sensitive indicators of concrete damage as pulsed coda wave analysis, but maintains its sensitivity at considerably much lower signal levels. Continuous and pulsed measurements were performed on a concrete slab subjected to cyclically increased damage level. In the unloaded phase each measurement type was performed at varying transmit signal levels. The result indicates the possibility of using a larger distance between transducers in high frequency health monitoring systems of concrete structures, where attenuation of propagating waves is strong.
27
Coda Wave Interferometry for Estimating Nonlinear Behavior in Seismic Velocity
Roel Snieder, Alexandre Grêt, Huub Douma et al. · Science · 2002 · 626 citations
Concrete structural health monitoring using embedded piezoceramic transducers
Gangbing Song, Hua Gu, Y. L. Mo et al. · Smart Materials and Structures · 2007 · 478 citations