Accelerated Testing Validation

Rangachary Mukundan, Greg James, John Davey, David A. Langlois, Dennis Torraco, Wonseok Yoon, Adam Z. Weber, Rodney L. Borup

ECS Transactions · 2011 · 33 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

Accelerated Stress Tests (ASTs) were performed on 2 different MEAs (designated P5 and HD6) from Ballard Power Systems. These MEAs were also incorporated into stacks and operated in fuel cell bus modules that were either operated in the field (three P5 buses) in Hamburg, or on an Orange county transit authority drive cycle in the laboratory (HD6 bus module). Qualitative agreement was found in the degradation mechanisms and rates observed in the AST and in the field. The HD6 based MEAs exhibited lower voltage degradation rates (due to catalyst corrosion) and slower membrane degradation rates in the field as reflected by their superior performance in the high potential hold and open-circuit potential AST tests. To quantitatively correlate lab ASTs to field degradation rates, various degradation stressors including temperature, RH, start/stops and voltage cycles, which are not constant in the field, must be accounted for.