Magnetic Resonance in Medicine · 2015 · 835 citations · 42 references
MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyDiffusion ImagingMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingNeuroimaging PhysicsPrincipal Component AnalysisDiffusion Magnetic Resonance ImagingImage Noise AssessmentMagnetic ResonanceMagnetic Resonance PhysicsNoise MappingPrincipal ComponentsRobust EstimationSingular Value Decomposition
Principal component analysis eigenvalues from noise follow the Marchenko–Pastur distribution, parameterized by the noise level. The study aims to estimate spatially varying noise maps from redundant magnitude MR images. By exploiting redundancy in multidirectional diffusion MRI data, the authors identify noise‑only principal components and estimate local noise levels via singular value decomposition of voxel‑direction matrices. The method achieves ~1% error, avoids artifactual features seen in existing techniques, and is validated by simulations and experiments showing accurate, precise, robust local noise estimation. Published in Magn Reson Med 76:1582–1593 (2016); © 2015 International Society for Magnetic Resonance in Medicine.
Purpose To estimate the spatially varying noise map using a redundant series of magnitude MR images. Methods We exploit redundancy in non‐Gaussian distributed multidirectional diffusion MRI data by identifying its noise‐only principal components, based on the theory of noisy covariance matrices. The bulk of principal component analysis eigenvalues, arising due to noise, is described by the universal Marchenko–Pastur distribution, parameterized by the noise level. This allows us to estimate noise level in a local neighborhood based on the singular value decomposition of a matrix combining neighborhood voxels and diffusion directions. Results We present a model‐independent local noise mapping method capable of estimating the noise level down to about 1% error. In contrast to current state‐of‐the‐art techniques, the resultant noise maps do not show artifactual anatomical features that often reflect physiological noise, the presence of sharp edges, or a lack of adequate a priori knowledge of the expected form of MR signal. Conclusions Simulations and experiments show that typical diffusion MRI data exhibit sufficient redundancy that enables accurate, precise, and robust estimation of the local noise level by interpreting the principal component analysis eigenspectrum in terms of the Marchenko–Pastur distribution. Magn Reson Med 76:1582–1593, 2016. © 2015 International Society for Magnetic Resonance in Medicine
42
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Mark A. Griswold, Peter M. Jakob, Robin M. Heidemann et al. · Magnetic Resonance in Medicine · 2002 · 5.3K citations · Full text