Characterization and Correction of Relative Humidity Measurements from Vaisala RS80-A Radiosondes at Cold Temperatures

Larry M. Miloshevich, Holger Vömel, A. Paukkunen, Andrew J. Heymsfield, S. J. Oltmans

Journal of Atmospheric and Oceanic Technology · 2001 · 221 citations · 20 references

DOIFull text

Open access

Concepts

Abstract

Radiosonde relative humidity (RH) measurements are known to be unreliable at cold temperatures. This study characterizes radiosonde RH measurements from Vaisala RS80-A thin-film capacitive sensors in the temperature range 0 to 70C. Sources of measurement error are identified, and two approaches for correcting the errors are presented. The corrections given in this paper apply only to the Vaisala RS80-A sensor, although the RS80-H sensor is briefly discussed for comparison.

References