IEEE Transactions on Nuclear Science · 2015 · 10 citations · 3 references
EngineeringElectrical EngineeringNuclear EngineeringField-programmable Gate ArraysInstrumentationReconfigurable ComputingData AcquisitionData Acquisition SystemsDetector TechnologyDigital Signal ProcessingPhotodetectorsRadiation DetectorsAvalanche Photodiode DetectorsAvalanche PhotodiodesData Acquisition ElectronicsData ProcessingDetector Readout ElectronicsLow-noise AmplifiersPhotodiodesTransimpedance Amplifiers
The prototype of uniquely designed complex data acquisition system for ITER divertor Thomson scattering diagnostic was developed. It allows recording short duration (3-5 ns) scattered pulses with 2 GHz sampling rate and 10-bit total resolution in oscilloscope mode. The system consists of 48 photo detector modules with 0-200 MHz bandwidth, 48 simultaneously sampling ADC modules and synchronization subsystem. The photo detector modules are based on avalanche photodiodes (APD) and ultra-low noise transimpedance amplifiers. ADC modules include fast analog to digital convertors and digital units based on the FPGA (Field-Programmable Gate Array) for data processing and storage. The synchronization subsystem is used to form triggering pulses and to organize the simultaneously mode of ADC modules operation.
3
Physical aspects of divertor Thomson scattering implementation on ITER
R.A. Pitts, P. Andrew, I.M. Bukreev et al. · Nuclear Fusion · 2014 · 40 citations
Double-grating polychromator for laser-aided plasma diagnostics
G. T. Razdobarin, A. N. Shilnikov, S. Yu. Tolstjakov et al. · Review of Scientific Instruments · 2004 · 11 citations
Natural Sciences, Physics, Optics +11