2006 · 29 citations · 0 references
EngineeringElectrical EngineeringElectric MachinesElectromagneticsElectromagnetismDirect Current MachinesElectric MotorsLosses In Electric MachinesMachine WindingsMagnetic Circuit AnalysisPermanent Magnet MachinesConcentrated WindingsCore Loss ModelingEddy Current AnalysisEddy Current LossesIron LossesPermanent Magnet LossesPermanent Magnet Synchronous MachinesStator Windings
The objective of this paper is to calculate the eddy-current losses in the solid back-iron of permanent-magnet (PM) machines with concentrated fractional-pitch stator windings. PM machines with fractional-pitch stator windings are increasingly used a lot because of their cost-effectiveness. The paper derives a model for these eddy-current losses. Although the correlation between the model and the measurements is not perfect, some important conclusions can be drawn. In machines with full-pitch distributed windings, the eddy-current losses in the back-iron are negligible, while in machines with fractional-pitch windings, these losses are too high to be acceptable.