Journal of Cardiac Failure · 2015 · 108 citations · 7 references
MedicineCardiologyInternal MedicineCardiac RehabilitationCardiovascular PharmacotherapyInterventional CardiologyAutonomic Nervous SystemFunctional Electrical StimulationHeart FailureVagus Nerve StimulationCervical Vagus Nerve StimulationChronic Heart Failure ManagementHeart Failure SymptomsImplantable Vagus Nerve StimulationLeft Ventricular Ejection Fraction DeclineTherapeutic EffectivenessTranscutaneous Vagus Nerve StimulationVagal Stimulation
OBJECTIVE: Evaluate the effects of a novel autonomic regulation therapy (ART) via vagus nerve stimulation (VNS) in patients with chronic heart failure (HF) and reduced left ventricular ejection fraction during a 12-month follow-up period. METHODS: The Autonomic Regulation Therapy for the Improvement of Left Ventricular Function and Heart Failure Symptoms (ANTHEM-HF) study enrolled 60 subjects with New York Heart Association class II-III HF and low left ventricular ejection fraction (≤40%), who received open-loop ART using VNS randomized to left or right cervical vagus nerve placement and followed for 6 months after titration to a therapeutic output current (2.0 ± 0.6 mA). Patients received chronic stimulation at a frequency of 10 Hz and pulse duration of 250 µsec. Forty-nine subjects consented to participate in an extended follow-up study for an additional 6 months (12 months total posttitration) to determine whether the effects of therapy were maintained. RESULTS: During the 6-month extended follow-up period, there were no device malfunctions or device-related serious adverse effects. There were 7 serious adverse effects unrelated to the device, including 3 deaths (2 sudden cardiac deaths, 1 worsening HF death). There were 5 nonserious adverse events that were adjudicated to be device-related. Safety and tolerability were similar, and there were no significant differences in efficacy between left- and right-sided ART. Overall, mean efficacy measure values at 12 months were not significantly different from mean values at 6 months. CONCLUSIONS: Chronic open-loop ART via left- or right-sided VNS continued to be feasible and well-tolerated in patients with HF with reduced EF. Improvements in cardiac function and HF symptoms seen after 6 months of ART were maintained at 12 months.
7
Prospective Study of Heart Rate Variability and Mortality in Chronic Heart Failure
James Nolan, Phillip D Batin, Richard Andrews et al. · Circulation · 1998 · 1.2K citations
Rajendra Kumar Premchand, Kamal Sharma, Sanjay Mittal et al. · Journal of Cardiac Failure · 2014 · 378 citations