Radiology · 2008 · 42 citations · 19 references
MedicineCancer BiologyOncologyBiomedical OpticsMolecular ImagingMolecular OncologyFluorescence ImagingFluorescence MicroscopyNear-infrared ImagingTumor ImagingTumor MarkersTumor-associated AntigensCarcinoembryonic Antigen ImagingFluorescence Contrast AgentsFluorescence ProbesFluorescent ProbesIn Vivo Fluorescence ImagingIn Vivo StudiesNear-infrared Fluorescence ImagingSmall Animal Imaging
PURPOSE: To prospectively depict carcinoembryonic antigen (CEA)-expressing tumors in mice with a high-affinity probe consisting of a near-infrared (NIR) fluorochrome and the clinically used anti-CEA antibody fragment arcitumomab. MATERIALS AND METHODS: This study was approved by the regional animal committee. By coupling a NIR fluorescent (NIRF) cyanine dye (DY-676) to a specific antibody fragment directed against CEA (arcitumomab) and a nonspecific IgG Fab fragment, a bio-optical high-affinity fluorescent probe (anti-CEA-DY-676) and a low-affinity fluorescent probe (FabIgG-DY-676) were designed. The dye-to-protein ratios were determined, and both probes were tested for NIRF imaging in vitro on CEA-expressing LS-174T human colonic adenocarcinoma cells and CEA-nonexpressing A-375 human melanoma cells by using a bio-optical NIR small-animal imager. In vivo data of xenografted LS-174T and A-375 tumors in mice (n = 10) were recorded and statistically analyzed (Student t test). RESULTS: The dye-to-protein ratios were determined as 3.0-3.5 for both probes. In vitro experiments revealed the specific binding of the anti-CEA-DY-676 probe on CEA-expressing cells as compared with CEA-nonexpressing cells; the FabIgG-DY-676 probe showed a markedly lower binding affinity to cells. In vivo LS-174T tumors xenografted in all mice could be significantly distinguished from A-375 tumors with application of the anti-CEA-DY-676 but not with that of the FabIgG-DY-676 at different times (2-24 hours, P < .005) after intravenous injection of the probes. Semiquantitative analysis revealed maximal fluorescence signals of anti-CEA-DY-676 to CEA-expressing tumors about 8 hours after injection. CONCLUSION: Findings of this study indicate the potential use of the high-affinity probe anti-CEA-DY-676 for specific NIRF imaging in in vivo tumor diagnosis.
19
Receptor-targeted optical imaging of tumors with near-infrared fluorescent ligands
Andreas Becker, Carsten Hessenius, Kai Licha et al. · Nature Biotechnology · 2001 · 520 citations
Near-infrared fluorescent imaging of tumor apoptosis.
Alexander Petrovsky, Eyk Schellenberger, Lee Josephson et al. · PubMed · 2003 · 206 citations
Medicine, Cell Biology, Oncology +17
Steven A. Soper, Quincy L. Mattingly · Journal of the American Chemical Society · 1994 · 197 citations