A resonant beam detector for Tevatron tune monitoring

Donald Martin, B. Fellenz, C. J. Hood, M. Johnson, Robert E. Shafer, R. Siemann, J. Zurawski

2003 · 13 citations · 1 references

DOIFull text

Open access

Concepts

Abstract

An inductively resonated balanced stripline pickup has been constructed for observing tune spectra. The device is a sensitive betatron oscillation and Schottky noise pickup, providing a 25-dB gain over untuned detectors of like geometry. The electrodes are motorized, allowing remote adjustment of the device center and aperture. To tune the resonator onto the 21.4-MHz operating frequency, a motorized capacitor is employed. Quadrature signals from a pair of detectors have enabled observation of individual proton and antiproton coherent motions to nanometer levels.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

1