Publication | Closed Access
Continuous and 4 h infusion of amphotericin B: a comparative study involving high-risk haematology patients
73
Citations
25
References
2004
Year
CI-AmB appears to be significantly less nephrotoxic than 4 h infusion AmB in haematology patients with fever and neutropenia--including high-risk bone-marrow transplant recipients--without increasing mortality. An AmB infusion rate of <0.08 mg/kg/h appears to be a safe threshold, associated with reduced renal impairment.