American Journal of Neuroradiology · 2010 · 383 citations · 15 references
MedicineNeurosurgerySurgeryCerebrovascular SurgeryFluid DynamicsVascular SurgeryAneurysm RepairAneurysm SurgeryAneurysm MechanicsCerebral Aneurysm RuptureComputational HemodynamicsFlow DiversionGiant Aneurysm SurgeryGiant Aneurysm TreatmentRuptured Intracranial Aneurysm ManagementStent-assisted Aneurysm Treatment
BACKGROUND AND PURPOSE: Flow-diverting approaches to intracranial aneurysm treatment had many promising early results, but recent apparently successful treatments have been complicated by later aneurysm hemorrhage. We analyzed 7 cases of aneurysms treated with flow diversion to explore the possible rupture mechanisms. MATERIALS AND METHODS: CFD analysis of pre- and posttreatment conditions was performed on 3 giant aneurysms that ruptured after treatment and 4 successfully treated aneurysms. Pre- and posttreatment hemodynamics were compared including WSS, relative blood flows, vascular resistances, and pressures, to identify the effects of flow-diverter placements. RESULTS: Expected reductions in aneurysm velocity and WSS were obtained, indicating effective flow diversion from the sac into the parent artery, consistent with periprocedural observations. In each case with postaneurysm rupture, the result of flow diversion led to an increase in pressure within the aneurysm. This pressure increase is related to larger effective resistance in the parent artery from placement of the devices and, in 2 cases, the reduction of a preaneurysm stenosis. CONCLUSIONS: Flow-diversion devices can cause intra-aneurysmal pressure increases, which can potentially lead to rupture, especially for giant aneurysms. This relates both to changes in the parent artery configuration, such as reduction of a proximal stenosis, and to the flow diversion into higher resistance parent artery pathways combined with cerebral autoregulation, leading to higher pressure gradients. These may be important effects that should be considered when planning interventions. Potentially dangerous cases could be identified with angiography and/or patient-specific CFD models.
15
CURATIVE ENDOVASCULAR RECONSTRUCTION OF CEREBRAL ANEURYSMS WITH THE PIPELINE EMBOLIZATION DEVICE
Pedro Lylyk, Carlos Miranda, Rosana Ceratto et al. · Neurosurgery · 2009 · 803 citations
Medicine, Neurosurgery, Surgery +14
István Szikora, Zsolt Berentei, Zsolt Kulcsár et al. · American Journal of Neuroradiology · 2010 · 565 citations · Full text
Medicine, Neurosurgery, Surgery +12
A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular Aneurysms
David F. Kallmes, Yong Hong Ding, Daying Dai et al. · Stroke · 2007 · 452 citations · Full text
Medicine, Neurosurgery, Surgery +9