CNC‐Milled Titanium Frameworks Supported by Implants in the Edentulous Jaw: A 10‐Year Comparative Clinical Study

85

Citations

36

References

2009

Year

Abstract

The frequency of complications was low with similar clinical and radiological performance for both groups during 10 years. CNC-milled titanium frameworks are a viable alternative to gold-alloy castings for restoring patients with implant-supported prostheses in the edentulous jaw.