U-value meters in theory and practice

J.B. Siviour, D.A. McIntyre

Building Services Engineering Research and Technology · 1982 · 11 citations · 0 references

Concepts

Abstract

U-value meters estimate the conductance of a wall in situ from simultaneous measurements of heat flux and temperature difference. The difficulty in achieving steady state conditions can give rise to considerable errors; the effects of inside and outside temperature variations, and of sunshine on the outer surface are analysed mathematically. The performance of U-value meters in practice is described, and the paper gives detailed recommendations for successful use.