Radiology · 2012 · 96 citations · 25 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic RadiologyChest RadiologyDiffusion ImagingMagnetic Resonance ImagingMedical ImagingPleural DiseasePleural Disease ImagingApparent Diffusion Coefficient AnalysisHistopathologic ExaminationMagnetic ResonanceMagnetic Resonance PhysicsMalignant Pleural Disease ImagingPleural Lesion DetectionPleural Malignancy ImagingPleural Space Imaging
PURPOSE: To investigate the use of diffusion-weighted (DW) imaging for differentiating benign lesions from malignant pleural disease (MPD) and to retrospectively assess dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging acquisitions to find out whether combining these measurements with DW imaging could improve the diagnostic value of DW imaging. MATERIALS AND METHODS: This study was approved by the local ethics committee, and all patients provided written informed consent. Thirty-one consecutive patients with pleural abnormalities suspicious for MPD underwent whole-body positron emission tomography (PET)/computed tomography (CT) and thorax MR examinations. Diagnostic thoracoscopy with histopathologic analysis of pleural biopsies served as the reference standard. First-line evaluation of each suspicious lesion was performed by using the apparent diffusion coefficient (ADC) calculated from the DW image, and the optimal cutoff value was found by using receiver operating characteristic curve analysis. Afterward, DCE MR imaging data were used to improve the diagnosis in the range of ADCs where DW imaging results were equivocal. RESULTS: Sensitivity, specificity, and accuracy of PET/CT for diagnosis of MPD were 100%, 35.3%, and 64.5%. The optimal ADC threshold to differentiate benign lesions from MPD with DW MR imaging was 1.52 × 10(-3) mm(2)/sec, with sensitivity, specificity, and accuracy of 71.4%, 100%, and 87.1%, respectively. This result could be improved to 92.8%, 94.1%, and 93.5%, respectively, when DCE MR imaging data were included in those cases where ADC was between 1.52 and 2.00 × 10(-3) mm(2)/sec. A total of 20 patients had disease diagnosed correctly, nine had disease diagnosed incorrectly, and two cases were undetermined with PET/CT. DW imaging helped stage disease correctly in 27 patients and incorrectly in four. The undetermined cases at PET/CT were correctly diagnosed at MR imaging. CONCLUSION: DW imaging is a promising tool for differentiating MPD from benign lesions, with high accuracy, and supplementation with DCE MR imaging seems to further improve sensitivity.
25
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Denis Le Bihan, D Lallemand, Michèle Aubin et al. · Radiology · 1988 · 3.2K citations
A combined PET/CT scanner for clinical oncology.
Thomas Beyer, D.W. Townsend, T. Brun et al. · PubMed · 2000 · 1.6K citations
Arnaud Scherpereel, Philippe Astoul, Thierry Berghmans et al. · European Respiratory Journal · 2009 · 636 citations · Full text
Renal Lesions: Characterization with Diffusion-weighted Imaging versus Contrast-enhanced MR Imaging
Bachir Taouli, Ravi Thakur, Lorenzo Mannelli et al. · Radiology · 2009 · 323 citations