European Respiratory Journal · 2002 · 543 citations · 14 references
PharmacyPharmacologyPharmacotherapyPulmonary Function TestingPulmonologyRespiratory PharmacotherapyAsthma ManagementBronchodilator TherapyInhalation TherapyInhaled Medication AdministrationMetered-dose InhalersRespiratory MedicineAsthma Medication Inhalation DevicesAsthma Medication ManagementInhalation Device TechniqueInhaled Corticosteroid AdministrationMetered-dose Inhaler UsePressurized Metered Dose Inhalers
The study examined whether improper use of pressurized metered‑dose inhalers is linked to poorer asthma control in patients treated with inhaled corticosteroids. General practitioners recruited 4,078 adult asthmatics on pMDI‑administered inhaled corticosteroids and on‑demand β2‑agonists, assessed inhalation technique, and calculated an asthma instability score from symptoms, medication use, and healthcare visits. Misuse of pMDIs was observed in 71% of patients—primarily due to poor coordination—and was associated with higher asthma instability scores (3.93 vs 2.86), especially among poor coordinators (4.38 vs 3.56), highlighting the importance of technique evaluation and coordination‑supporting devices.
This study assessed whether the improper use of pressurized metered-dose inhalers (pMDIs) is associated with decreased asthma control in asthmatics treated by inhaled corticosteroids (ICS). General practitioners (GPs) included consecutive asthmatic outpatients treated by pMDI-administered ICS and on-demand, short-acting β 2 -agonists. They measured an asthma instability score (AIS) based on daytime and nocturnal symptoms, exercise-induced dyspnoea, β 2 -agonist usage, emergency-care visits and global perception of asthma control within the preceding month; the inhalation technique of the patient also was assessed. GPs (n=915) included 4,078 adult asthmatics; 3,955 questionnaires were evaluable. pMDI was misused by 71% of patients, of which 47% was due to poor coordination. Asthma was less stable in pMDI misusers than in good users (AIS: 3.93 versus 2.86, p<0.001). Among misusers, asthma was less stable in poor coordinators (AIS: 4.38 versus 3.56 in good coordinators, p<0.001). To conclude, misuse of pressurized metered-dose inhalers, which is mainly due to poor coordination, is frequent and associated with poorer asthma control in inhaled corticosteroid-treated asthmatics. This study highlights the importance of evaluating inhalation technique and providing appropriate education in all patients, especially before increasing inhaled corticosteroid dosage or adding other agents. The use of devices which alleviate coordination problems should be reinforced in pressurized metered-dose inhaler misusers.
14
GLOBAL STRATEGY FOR ASTHMA MANAGEMENT AND PREVENTION
Romain Pauwels · Arerugī/Arerugi · 1996 · 10.1K citations
Pharmacy, Chronic Disease Prevention, Preventive Medicine +10
Differences between asthma exacerbations and poor asthma control
Helen K. Reddel, Sandra Ware, Guy B. Marks et al. · The Lancet · 1999 · 280 citations
Medical Personnel's Knowledge of and Ability to Use Inhaling Devices
Nicola A. Hanania, Richard Wittman, Steven Kesten et al. · CHEST Journal · 1994 · 259 citations