IEEE Transactions on Industrial Electronics · 2005 · 41 citations · 8 references
EngineeringElectrical EngineeringElectric MachinesMotor ControlPower ElectronicsElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesElectric MotorsPermanent Magnet MachinesSynchronous MachinesInterior Permanent Magnet MachinesInterior Permanent Magnet Synchronous MachinesMotor Drive ControlPermanent Magnet Synchronous Motor DrivesRotor Position EstimationSaliency-based ControlStator WindingsVoltage Source Inverters
In this paper a novel interior permanent-magnet (IPM) motor's rotor position extraction method from the carrier-frequency component signal, derived from pulsewidth-modulated (PWM) inverter switching, using two reference frames is presented. This method has been utilized for IPM motor vector control without a mechanical rotor position detector, extracting rotor position angle from the switching carrier-frequency (10 kHz) component current. It is effective for IPM motors, which have magnetic saliency, sinusoidal distributed stator winding, and are supplied by a PWM voltage-source inverter. The performance of two IPM motors' vector control without mechanical rotor position detector utilizing this method has been investigated. Experimental results demonstrating good dynamic and steady-state performance achieved are presented and discussed.
8