Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · 1986 · 528 citations · 0 references
EngineeringChemical EngineeringChemistryBiosensorsElectrochemistryEnzymologyConducting PolymersElectrochemical BiosensorsElectrochemical DetectionElectrochemical SensorsEnzymatic BiosensorsEnzyme-based BiosensorsAmperometric SensorsElectrochemical BiosensingElectrochemical SensingEnzyme ActivityGlucose BiosensorsGlucose OxidaseGlucose SensorsPlatinum Electrodes
The study explores the potential of a novel glucose oxidase entrapment method for developing biosensors. Glucose oxidase is entrapped in a polypyrrole matrix electrochemically deposited on a printed platinum electrode, enabling operation as amperometric glucose sensors with or without soluble mediators. Enzyme activity within the polymer is proportional to that in the electropolymerisation medium, and the resulting sensors reach a steady state in 20–40 s with a current‑limited response.
A technique is described for the entrapment of glucose oxidase in a polypyrrole matrix electrochemically deposited on a printed platinum electrode. The enzyme activity incorporated into the polymer was quantified by spectrophotometric assay using a flow-through cell and found to be proportional to the activity in the electropolymerisation medium. Polymer-entrapped glucose oxidase electrodes can be operated as amperometric glucose sensors in the presence or absence of soluble mediators. These electrodes respond rapidly, reaching a steady state within 20–40 s, with the enzymatic response being current limiting. The potential of this new immobilisation technique to the development of biosensors is discussed.