Journal of Magnetic Resonance Imaging · 2004 · 59 citations · 20 references
MedicineRadiologyCardiac Nuclear MedicineClinical CardiologyDiagnostic RadiologyCardiac Nuclear ImagingCoronary Artery ImagingMyocardial Blood Flow QuantificationMyocardial Perfusion ImagingCardiac Myocardial Perfusion ImagingPerfusion Imaging ComparisonQuantitative Myocardial Perfusion ImagingQuantitative Perfusion ImagingSaturation Recovery PulsesSingle-photon Emission Computed Tomography Perfusion QuantificationTime-intensity Curves
PURPOSE: To compare signal-to-noise ratio (SNR), contrast-to-noise (CNR) ratio, and diagnostic accuracy of a newly developed saturation recovery (SR)-TrueFISP-two-dimensional (2D) sequence with an SR-TurboFLASH-2D sequence. MATERIALS AND METHODS: In seven healthy subjects and nine patients with coronary artery disease (CAD), contrast-enhanced perfusion imaging (with Gd-DTPA) was performed with SR-TrueFISP and SR-TurboFLASH sequences. Hypoperfused areas were assessed qualitatively (scale = 0-4). Furthermore, SNR and CNR were calculated and semiquantitative perfusion parameters were determined from signal intensity (SI) time curves. Standard of reference for patient studies was single-photon emission computer tomography (SPECT) and angiography. RESULTS: The perception of perfusion deficits was superior in TrueFISP images (2.6 +/- 1.0) than in TurboFLASH (1.4 +/- 0.6) (P < 0.001). Phantom measurements yielded increased SNR (143 +/- 34%) and CNR (158 +/- 64%) values for TrueFISP. In patient/volunteer studies SNR was 61% to 100% higher and signal enhancement was 110% to 115% higher with TrueFISP than with TurboFLASH. Qualitative and semiquantitative assessment of perfusion defects yielded higher sensitivities for detection of perfusion defects with TrueFISP (68% to 78%) than with TurboFLASH (44% to 59%). CONCLUSION: SR-TrueFISP-2D perfusion imaging provides superior SNR and CNR than TurboFLASH imaging. Moreover, the dynamic range of SIs was found to be higher with TrueFISP, resulting in an increased sensitivity for detection of perfusion defects.
20
Cine MR Angiography of the Heart with Segmented True Fast Imaging with Steady-State Precession
James Carr, Orlando P. Simonetti, Jeffrey M. Bundy et al. · Radiology · 2001 · 467 citations
Medicine, Cardiology, Radiology +17
Myocardial perfusion reserve: assessment with multisection, quantitative, first-pass MR imaging.
Norbert Wilke, Michael Jerosch‐Herold, Yang Wang et al. · Radiology · 1997 · 388 citations
Medicine, Cardiology, Radiology +17