High rate large dynamic range analog circuitry and digitizers for fast calorimetry

B. Hallgren, F. Bal, G.D. Barr, P. Buchholz, F. Formenti, W. Funk, Y. Kozhevnikov, A. Lacourt, G. Laverrière, M. Martini,

IEEE Transactions on Nuclear Science · 1996 · 12 citations · 3 references

Concepts

Abstract

This paper describes the issues encountered in the design of a large dynamic range digitizer for calorimetry. A gain switching technology developed for the liquid krypton calorimeter of the NA48 CP-violation experiment at CERN is described in detail. 14 bit dynamic range and better than 300 ps time resolution were achieved in beam tests with an 8 channel prototype. A mixed analog/digital ASIC has been developed. A 13,500 channel system is being produced which will be put into operation in 1996.

References

3