Journal of Applied Bacteriology · 1989 · 11 citations · 11 references
Life SciencesMicrobiologyBacteriologyDiagnostic MicrobiologyMicrobial PhysiologyBacterial GrowthRelative Biological EffectivenessAntibiotic Effects On GrowthGrowth Performance IndexMetabolic Activity AssaysRadiometric ValidationTotal Viable CountViable Cell CountViable Cell Counting
In a study involving 2760 tests, the BACTEC semi‐automatic radiometric method which measures bacterial metabolic activity and produces a BACTEC growth index, was compared with two conventional methods commonly used for determining growth, absorbance and viable counts. In 92% of radiometry tests the suppression of growth was inversely related to the antibiotic concentration. This compared with 83% for absorbance and 63% for viable counts. The radiometric method was found to be more rapid, easier to use and more reproducible in determining the effect of antibiotics on the activity of bacteria than viable counting or absorbance methods.
11
The estimation of the bactericidal power of the blood
A. A. Miles, S. S. Misra, J. O. Irwin · Epidemiology and Infection · 1938 · 3.6K citations · Full text
Laboratory Methods in Antimicrobial Chemotherapy
Paul C. Legolvan · Military Medicine · 1979 · 225 citations
Topley and Wilson's Principles of Bacteriology, Virology and Immunity
B. A. D. Stocker · JAMA · 1976 · 134 citations