Concepedia

Publication | Open Access

Fault-Tolerant Control Performance Comparison of Three- and Five-Phase PMSG for Marine Current Turbine Applications

79

Citations

28

References

2012

Year

Abstract

This paper deals with the use of permanent magnet multiphase generators in marine current turbines with the aim to highlight their fault-tolerance. In this context, the performances and the fault-tolerant capabilities of a five-phase permanent magnet synchronous generator are evaluated within a marine current turbine and compared to a classical three-phase generator. For both topologies, a robust nonlinear control strategy is adopted. The adopted control consists of an adaptive control approach that combines three strategies: a maximum power point tracking (MPPT), an optimal fault-adaptive reference current generation, and high-order sliding modes. Simulations are carried-out using a Matlab/Simulink-based marine current turbine simulator to analyze the generator performances during open-circuit faults. Conclusions are then derived regarding multiphase generators' key features for marine applications.

References

YearCitations

Page 1