British Journal of Radiology · 2004 · 213 citations · 13 references
MedicineNephrologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyDiffusion ImagingMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingRenal ImagingRenal Mass EvaluationDiffusion Mri AcquisitionDiffusion-weighted ContrastEcho Planar ImagingLesion Enhancement AssessmentSpin Echo ImagingSpin Echo SequencesT1-weighted ImagingTurbo Spin Echo
The purpose of this study was to evaluate the capability and the reliability of diffusion-weighted MRI in the evaluation of normal kidney and different renal lesions. 39 patients (10 normal volunteers and 29 patients with known renal lesions) underwent MRI of the kidneys by using a 1.5 T superconducting magnet. Axial fat suppressed turbo spin echo (TSE) T(2) and coronal fast field echo (FFE) T(1) or TSE T(1) weighted images were acquired for each patient. Diffusion-weighted (DW) images were obtained in the axial plane during breath-hold (17 s) with a spin-echo echo planar imaging (SE EPI) single shot sequence (repetition time (TR)=2883 ms, echo time (TE)=61 ms, flip angle=90 degrees ), with b value of 500 s mm(-2). 16 slices were produced with slice thickness of 7 mm and interslice gap of 1 mm. An apparent diffusion coefficient (ADC) map was obtained at each slice position. The ADC was measured in an approximately 1 cm region of interest (ROI) within the normal renal parenchyma, the detected renal lesions and the collecting system if dilated. ADC values in normal renal parenchyma ranged from 1.72 x 10(-3) mm(2) s(-1) to 2.65 x 10(-3) mm(2) s(-1), while ADC values in simple cysts (n=13) were higher (2.87 x 10(-3) mm(2) s(-1) to 4.00 x 10(-3) mm(2) s(-1)). In hydronephrotic kidneys (n=6) the ADC values of renal pelvis ranged from 3.39 x 10(-3) mm(2) s(-1) to 4.00 x 10(-3) mm(2) s(-1). In cases of pyonephrosis (n=3) ADC values of the renal pelvis were found to be lower than those of renal pelvis of hydronephrotic kidneys (0.77 x 10(-3) mm(2) s(-1) to 1.07 x 10(-3) mm(2) s(-1)). Solid benign and malignant renal tumours (n=7) showed ADC values ranging between 1.28 x 10(-3) mm(2) s(-1) and 1.83 x 10(-3) mm(2) s(-1). In conclusion diffusion-weighted MR imaging of the kidney seems to be a reliable way to differentiate normal renal parenchyma and different renal diseases. Clinical experience with this method is still preliminary and further studies are required.
13
Fast magnetic resonance diffusion‐weighted imaging of acute human stroke
Steven Warach, Daisy Chien, W. Li et al. · Neurology · 1992 · 881 citations
Abdominal diffusion mapping with use of a whole-body echo-planar system.
Felipe Martins Müller, Pottumarthi V. Prasad, Bettina Siewert et al. · Radiology · 1994 · 246 citations