Complications of Small Intestinal Submucosa for Corporal Body Grafting for Proximal Hypospadias

Trevor M. Soergel, Mark P. Cain, Martin Kaefer, Jordan Gitlin, Anthony J. Casale, Mary M. Davis, Richard C. Rink

The Journal of Urology · 2003 · 53 citations · 9 references

Abstract

Our experience using the 4-layer SIS resulted in 2 major complications requiring surgical correction during stage 2 repair. This rate exceeds the complications reported with either dermal or tunica vaginalis grafts. Currently we have stopped using SIS for corporal grafting.

References