Publication | Closed Access
Determination of ?-hydroxybutyric acid (GHB) in plasma and urine by headspace solid-phase microextraction and gas chromatography/positive ion chemical ionization mass spectrometry
54
Citations
36
References
2000
Year
-Hydroxybutyric AcidGas ChromatographyBioanalysisQuantitative AnalysisAnalytical ChemistryToxicologyUrine SamplesLiquid ChromatographyClinical ChemistryChromatographyBiochemistryMetabolomicsChromatographic AnalysisPharmacologyHeadspace Solid-phase MicroextractionMass SpectrometryForensic ToxicologyMedicinePharmacokineticsDrug Analysis
A new method for the qualitative and quantitative analysis of gamma-hydroxybutyric acid (GHB) in plasma and urine samples is described. It involves the conversion of GHB to gamma-butyrolactone (GBL), its subsequent headspace solid-phase microextraction (SPME), and detection by gas chromatography/positive ion chemical ionization mass spectrometry (GC/PICI-MS), using D(6)-GBL as internal standard. The assay is linear over a plasma GHB range of 1-100 microg/mL (n = 5, r = 0.999) and a urine GHB range of 5-150 microg/mL (n = 5, r = 0. 998). Relative intra- and inter-assay standard deviations, determined for plasma and urine samples at 5 and 50 microg/mL, are all below 5%. The method is simple, specific and reasonably fast. It may be applied for clinical and forensic toxicology as well as for purposes of therapeutic drug monitoring.
| Year | Citations | |
|---|---|---|
Page 1
Page 1