Radiology · 2002 · 73 citations · 24 references
MedicineNeurosurgeryRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingCerebrovascular ImagingMagnetic Resonance ImagingNeurovascular ImagingSinus ImagingVascular ImagingCerebral Vascular ImagingCerebral Venous SinusesContrast-enhanced AngiographyContrast-enhanced Magnetic Resonance AngiographyDural Venous SinusesInferior Sagittal SinusIntracranial Vessel ImagingVascular Visualization
PURPOSE: To compare the visualization of cerebral veins and dural sinuses at contrast material-enhanced three-dimensional (3D) fast low-angle shot (FLASH) magnetic resonance (MR) angiography, time-of-flight (TOF) MR angiography, and phase-contrast MR angiography. MATERIALS AND METHODS: The authors prospectively compared the two-dimensional source images, multiplanar reconstructed images, and maximum intensity projection angiograms obtained at contrast-enhanced 3D radio-frequency-spoiled FLASH MR angiography in 20 patients with those obtained at TOF and phase-contrast MR angiographic examinations. Two neuroradiologists in consensus determined the number of visualized cortical veins and graded the quality of visualization of veins and sinuses as intense and continuous, faint and continuous, or noncontinuous. Statistical analysis was performed with the nonparametric sign test and the Wilcoxon matched pairs sign rank test. RESULTS: The cortical veins, inferior sagittal sinus, and cavernous sinuses were visualized best with FLASH MR angiography (P <.003). The Trolard and Labbé veins were visualized equally well with the FLASH and TOF sequences. For septal, internal cerebral, and Rosenthal left basal vein visualization, phase-contrast MR angiography was inferior to the FLASH and TOF MR angiographic examinations (P <.05). The quality of visualization of the thalamostriate and Galen veins and of the superior sagittal, rectal, and transverse sinuses was the same at all MR angiographic examinations. CONCLUSION: Three-dimensional FLASH MR angiography depicts some venous structures better than do TOF and phase-contrast MR angiographic examinations. The depiction of other veins is the same with 3D FLASH and TOF sequences.
24
Cerebral venous thrombosis--a review of 38 cases.
Marie‐Germaine Bousser, J. Chiras, J Bories et al. · Stroke · 1985 · 780 citations
Treatment of dural sinus thrombosis using selective catheterization and urokinase
Michael Horowitz, Phillip D. Purdy, Hal Unwin et al. · Annals of Neurology · 1995 · 249 citations
Medicine, Neurosurgery, Surgery +14
Improved time-of-flight MR angiography of the brain with magnetization transfer contrast.
Robert R. Edelman, Seong-Cheol Ahn, Daisy Chien et al. · Radiology · 1992 · 196 citations
Heinrich P. Mattle, K U Wentz, Robert R. Edelman et al. · Radiology · 1991 · 171 citations