IEEE Transactions on Industry Applications · 2006 · 62 citations · 18 references
EngineeringElectrical EngineeringMining EngineeringElectric MachinesPower ElectronicsUnderground MiningAuxiliary VentilationElectric DrivesElectric Motor DrivesPower QualityVentilation SimulationHarmonic EffectsLow-pass Filter ResponseLow-pass FilteringLow-pass FiltersMechanical Ventilation In MinesMotor Drive InvertersVariable-frequency DrivesVariable-speed Motors
Underground mining is characterized by space constraints forcing the use of long cables to feed large machines, where the application of variable speed drives can generate overvoltages at the machine terminals. This paper presents the analysis and mitigation of harmful overvoltages detected in inverter-fed 1400-hp 13.8-kV motors used for air ventilation in an underground mine. The possible causes of the overvoltages, namely wave reflection and resonance, are described theoretically and simulated. On-site direct voltage measurements at the 13.8-kV motor terminals confirmed that resonance was the dominant phenomenon. Based on this study, a suitable low-pass filter was designed, constructed, and installed. Finally, the adequate operation of such filter is demonstrated by further on-site measurements.
18