Journal of Biomechanical Engineering · 1995 · 59 citations · 16 references
Natural SciencesBioengineeringBiomedical EngineeringBiomechanicsMechanical Behavior Of MaterialsMechanobiologyCompressive PropertiesMechanical TestingTissue MechanicsAxial Compression ResponseBiomechanical TestingCompression MechanicsCompression Properties
Uniaxial confined compression and swelling experiments on cylindrical specimens taken either in an axial or in a radial direction from a canine lumbar annulus fibrosus are presented. The loading protocol consisted of a combination of stepwise mechanical and chemical loading. Swelling and consolidation curves of normalized displacement versus square root of normalized time did not show a dependence on site or orientation of the specimen. All stages in which height increases, namely, conditioning, swelling, and desolidation show only slight differences in these normalized curves. Consolidation is initially faster, and later slower. The transport coefficient for axial specimens is higher than for radial specimens, for consolidation e.g., 3.14 +/- 1.56 10(-10) m2s(-1) and 1.11 +/- 0.33 10(-10) m2s(-1) respectively, the biphasic aggregate moduli are 1.01 +/- 0.31 MPa and 0.66 +/- 0.30 MPa, respectively.
16
Swelling Pressure of the Lumbar Intervertebral Discs
Jill Urban, J Mcmullin · Spine · 1988 · 478 citations
Biomechanical time‐tolerance of fresh cadaveric human spine specimens
Manohar M. Panjabi, Martin H. Krag, D. J. Summers et al. · Journal of Orthopaedic Research® · 1985 · 307 citations
Medicine, Surgery, Orthopedics +12
Swelling pressures of proteoglycans at the concentrations found in cartilaginous tissues
J Urban, Alice Maroudas, Michael T. Bayliss et al. · Biorheology · 1979 · 297 citations