Publication | Open Access
The New Generation System of Japan Standard Time at NICT
22
Citations
4
References
2008
Year
Electrical EngineeringNetwork TimingJapan Standard TimeEngineeringHydrogen MasersClock RecoveryComputer EngineeringSystems EngineeringMajor UpgradesInstrumentationClock SynchronizationNew Generation System
NICT has completed a set of major upgrades in its systems for the realization of Japan standard time. One of the most significant changes is the introduction of hydrogen masers as signal sources for UTC (NICT) instead of Cs atomic clocks. This greatly improves the short‐term stability of UTC (NICT). Another major change is the introduction of a newly developed 24‐channel dual‐mixer‐time‐difference system (DMTD) as the main tool for measurements. The reliability of the system is also improved by enhanced redundancy and monitoring systems. The new JST system has been in regular operation since February 2006.
| Year | Citations | |
|---|---|---|
Page 1
Page 1