Physics in Medicine and Biology · 2015 · 83 citations · 84 references
MedicineBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingComputed TomographyComputed Tomography PhysicsMedical ImagingScatter CorrectionTrauma ImagingAcute Brain Injury ImagingBeam Hardening Artifact ReductionBeam Hardening CorrectionCone-beam Computed Tomography (Cbct)Contrast ResolutionDetector Artifact CorrectionFlat-panel DetectorsMonte Carlo Scatter Correction
CT is the frontline imaging modality for diagnosis of acute traumatic brain injury (TBI), involving the detection of fresh blood in the brain (contrast of 30-50 HU, detail size down to 1 mm) in a non-contrast-enhanced exam. A dedicated point-of-care imaging system based on cone-beam CT (CBCT) could benefit early detection of TBI and improve direction to appropriate therapy. However, flat-panel detector (FPD) CBCT is challenged by artifacts that degrade contrast resolution and limit application in soft-tissue imaging. We present and evaluate a fairly comprehensive framework for artifact correction to enable soft-tissue brain imaging with FPD CBCT. The framework includes a fast Monte Carlo (MC)-based scatter estimation method complemented by corrections for detector lag, veiling glare, and beam hardening.The fast MC scatter estimation combines GPU acceleration, variance reduction, and simulation with a low number of photon histories and reduced number of projection angles (sparse MC) augmented by kernel de-noising to yield a runtime of ~4 min per scan. Scatter correction is combined with two-pass beam hardening correction. Detector lag correction is based on temporal deconvolution of the measured lag response function. The effects of detector veiling glare are reduced by deconvolution of the glare response function representing the long range tails of the detector point-spread function. The performance of the correction framework is quantified in experiments using a realistic head phantom on a testbench for FPD CBCT.Uncorrected reconstructions were non-diagnostic for soft-tissue imaging tasks in the brain. After processing with the artifact correction framework, image uniformity was substantially improved, and artifacts were reduced to a level that enabled visualization of ~3 mm simulated bleeds throughout the brain. Non-uniformity (cupping) was reduced by a factor of 5, and contrast of simulated bleeds was improved from ~7 to 49.7 HU, in good agreement with the nominal blood contrast of 50 HU. Although noise was amplified by the corrections, the contrast-to-noise ratio (CNR) of simulated bleeds was improved by nearly a factor of 3.5 (CNR = 0.54 without corrections and 1.91 after correction). The resulting image quality motivates further development and translation of the FPD-CBCT system for imaging of acute TBI.
84
The spectrum of disease in chronic traumatic encephalopathy
Ann C. McKee, Thor D. Stein, Christopher J. Nowinski et al. · Brain · 2012 · 2.1K citations · Full text
Diffuse axonal injury and traumatic coma in the primate
Thomas A. Gennarelli, Lawrence E. Thibault, J. H. Adams et al. · Annals of Neurology · 1982 · 1.5K citations
Medicine, Neurology, Neuroscience +13
An Inversion Formula for Cone-Beam Reconstruction
Heang K. Tuy · SIAM Journal on Applied Mathematics · 1983 · 933 citations
Engineering, Radiology, Optics +12