IEEE Transactions on Energy Conversion · 1999 · 148 citations · 12 references
EngineeringElectrical EngineeringElectric MachinesFault ToleranceFault-tolerant SystemsElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesFault DetectionMachine WindingsSwitched Reluctance MachinesFault Diagnosis In Motor DrivesFault Tolerant OperationFault-tolerant Drive SystemsInsulation Failure DetectionMotor Drive SystemsMotor Fault ToleranceSwitched Reluctance Motor DrivesSwitched Reluctance Motors
This paper examines winding faults in a demonstrator drive, based on a specification for an aircraft fuel pump. This drive has been designed with a degree of inherent fault tolerance and is capable of continued operation in the presence of a variety of faults. Some of the most severe faults arise from winding insulation failure within a phase of the machine. A method of detecting turn to turn short circuits which can result from winding insulation breakdown is presented, along with a strategy for continued post fault operation of the drive. The detection method operates in real time, requires no additional sensors and is sufficiently sensitive to detect even a single shorted turn.
12
Fault-tolerant permanent magnet machinedrives
B.C. Mecrow, A.G. Jack, J.A. Haylock et al. · IEE Proceedings - Electric Power Applications · 1996 · 372 citations
Engineering, Electrical Engineering, Systems Engineering +17