MedicineRadiation OncologyRadiologyDiagnostic ImagingDiagnostic RadiologyTreatment PlanningComputed TomographyComputed Tomography Dose ManagementComputed Tomography PhysicsRadiation TherapyTreatment Planning Dose CalculationArtifact ReductionImaging-based Treatment PlanningKilovoltage ImagingMegavoltage ImagingMetal Artifact CorrectionMetal Artifact ReductionPatient Radiation Dose OptimizationRadiation Dose Optimization
BACKGROUND: To determine the effect of different imaging options and the most efficient imaging strategy for treatment planning of patients with hip prostheses. METHODS: The planning kilovoltage CT (kVCT) and daily megavoltage CT (MVCT) studies for three prostate cancer patients with bilateral hip prostheses were used for creating hybrid kVCT/MVCT image sets. Treatment plans were created for kVCT images alone, hybrid kVCT/MVCT images, and MVCT images alone using the same dose prescription and planning parameters. The resulting dose volume histograms were compared. The orthopedic metal artifact reduction (O-MAR) reconstruction tool for kVCT images and different MVCT options were investigated with a water tank fit with double hip prostheses. Treatment plans were created for all imaging options and calculated dose was compared with the one measured by a pin-point ion chamber. RESULTS: On average for three patients, the D35% for the bladder was 8% higher in plans based on MVCT images and 7% higher in plans based on hybrid images, compared to the plans based on kVCT images alone. Likewise, the D35% for the rectum was 3% higher than the kVCT based plan for both hybrid and MVCT plans. The average difference in planned D99% in the PTV compared to kVCT plans was 0.9% and 0.1% for MVCT and hybrid plans, respectively. For the water tank with hip prostheses phantom, the kVCT plan with O-MAR correction applied showed better agreement between the measured and calculated dose than the original image set, with a difference of -1.9% compared to 3.3%. The measured doses for the MVCT plans were lower than the calculated dose due to image size limitations. The best agreement was for the kVCT/MVCT hybrid plans with the difference between calculated and measured dose around 1%. CONCLUSION: MVCT image provides better visualization of patient anatomy and hybrid kVCT/MVCT study enables more accurate calculations using updated MVCT relative electron density calibration.
17
The use of megavoltage CT (MVCT) images for dose recomputations
K Langen, Sanford L. Meeks, Darrell O. Poole et al. · Physics in Medicine and Biology · 2005 · 181 citations
Iterative approaches to dose optimization in tomotherapy
David Shepard, G Olivera, Paul Reckwerdt et al. · Physics in Medicine and Biology · 1999 · 154 citations