Diagnosing infection in hip replacements. The use of fine-needle aspiration and radiometric culture

Paul R. Roberts, AJ Walters, DJ McMinn

Journal of Bone and Joint Surgery - British Volume · 1992 · 83 citations · 0 references

Concepts

Abstract

In 78 consecutive patients, we performed fine-needle aspiration of the hip before revision surgery. At the revision operation biopsies were taken from the capsule and joint tissues. The aspirate and the homogenised soft-tissue specimens were cultured using a radiometric technique. Fifteen hips proved to be infected and 63 sterile on culture of the tissues taken during revision surgery; 94% of the aspiration results were correct. The sensitivity of the technique was 87% and the specificity 95%. Fine-needle aspiration combined with a radiometric culture technique is a simple and reliable method of diagnosing infection of hip prostheses.